Product Description
The LiftMaster CPICARD Interface Module is designed to connect select monitored entrapment protection devices to non-monitored commercial door operators. This module allows installers to integrate LiftMaster monitored photo eyes, monitored light curtains, or monitored safety edges where a monitored input is not native to the operator. The CPICARD provides signal compatibility between the device and the operator, enabling controlled safety input without converting the operator into a fully monitored system.
When used with monitored photo eyes or monitored safety edges, entrapment protection is monitored only between the safety device and the CPICARD itself. This configuration does not meet the requirements of a fully monitored entrapment protection system, making proper application critical during installation and code review.
Specifications
- Compatible with LiftMaster CPS-U, CPS-OPEN4, CPS-RPEN4 monitored photo eyes
- Supports LiftMaster LC36M monitored light curtain
- Supports LiftMaster OES monitored safety edge systems
- Interfaces monitored safety devices with non-monitored operators
- Monitoring limited to device-to-module connection only
- Does not convert operator into a fully monitored safety system
- Designed for commercial and industrial door applications
- Compact card-style module for clean integration inside operator housings
- Alias part numbers - 041K4629, 1C4489, 41K4629, 41C4489, CPI